P2298
O2 Sensor Out of Range During Deceleration (Bank 2 Sensor 1)
P2298 is the bank 2 version of P2297 and exists only on engines with two cylinder banks, each with its own upstream oxygen sensor. Three GM tables show the two readings of the code. The 2005 3.5L V6 (L66) tests during fuel cut-off with coolant above 69 °C and below 2,200 rpm, faulting a wide-band output above 4.5 V or below 2.9 V, over two drive cycles. The Bosch-managed 2005 V6 (LP1/LY7) works the other way round and flags a signal above 3.7 V for 10 s while every injector is firing and the target is richer than lambda 1.6. GM's 2024 tables (24OBDG07) set it for a lambda equivalent above 12 from the corrected pump current with the ceramic hotter than 655 °C, 10 s, two trips. No bulletin names P2298. Bank 2 is the side without cylinder 1.
Possible causes
- Bank 2 upstream wide-band sensor aged or contaminated high
- Exhaust leak on bank 2 ahead of the sensor medium
- Damaged sensor lead or connector on bank 2 low
Symptoms
- Malfunction indicator lamp on after two trips
- Usually no noticeable change in driving behaviour
- Bank 2 fuel trim values may look unusual
Inspection / repair
- Difficulty: easy
- DIY: possible
What Pro shows you for P2298
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 1 affected component(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?