Powertrain
generic / SAE
P2254
O2 Sensor Negative Current Control Circuit Low (Bank 2 Sensor 1)
Bank 2 counterpart to P2252. The Vs negative line on the wide-band oxygen sensor at bank 2, sensor 1 is below the lower threshold.
SystemPowertrain
Typegeneric / SAE
GroupP2
Range / number2 / 54
Possible causes
- Vs negative line shorted to ground high
- Nernst cell return open inside sensor medium
- Connector pins corroded - high contact resistance low
Symptoms
- Check engine light on
- Increased fuel consumption
- Possible rough idle or hesitation
- Failed emissions test
Inspection / repair
- Difficulty: medium
- DIY: possible
- Estimated cost: 150–500 €
- Estimated time: 0.5–2 h
- Component: oxygen sensor upstream b2
- Component: oxygen sensor wiring
- MIL / check engine light
- emissions-relevant
- drive cycle required
Sources
References
sae:J2012