P224A
NOx Sensor Heater Resistance (Bank 1 Sensor 1)
P224A concerns the heater of the upstream NOx sensor on bank 1, the one before the SCR catalyst. Its electrical resistance rises with temperature, so the sensor electronics use it to hold the ceramic element at working heat. The code says that resistance is outside its allowed band, pointing to an aged or damaged element or a contact problem. No maker documents P224A publicly. GM performs the same test on the 3.0 L LZ0 Duramax (2025) but reports it as P2209: the measured resistance may differ from the target by no more than 3 %, judged on 50 of 100 readings once the supply has been above 10.8 V for 45 s and the dew point was passed 180 s earlier, Type B. A sensor with this fault reads NOx unreliably; P224B is the downstream sensor.
Possible causes
- Heating element of the NOx sensor aged or cracked high
- Corroded or loose contacts in the sensor connector medium
- Unstable supply voltage to the sensor module low
Symptoms
- Check engine light
- SCR efficiency or NOx plausibility codes may follow
Inspection / repair
- Difficulty: medium
- DIY: possible
What Pro shows you for P224A
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.