P223E
O2 Sensor Reference Resistance Out Of Range (Bank 1)
P223E checks the internal resistance of the reference (Nernst) cell in the bank 1 wide-band sensor. That resistance falls as the ceramic heats up, so the ECM uses it as a thermometer; Bosch specifies 300 ohms nominal for the LSU 4.9 at operating temperature. GM's tables (2016-2019) convert the value supplied by the interface chip into an element temperature and flag anything below 700 °C or above 1,000 °C in 80 % of samples (64 of 80 in 2018, 128 of 160 in 2016/2019), starting 20 s after heater warm-up; the code is Type B. GM bulletin 16-NA-266 covers 2016-2017 ATS, CTS, CT6, Camaro, Malibu and Envision with the 2.0 turbo LTG: a voltage spike inside the ECM sets P223E or P0132 and also blocks remote start, cured by reprogramming. P223F is bank 2, P0135 the heater itself.
Possible causes
- Aged sensor whose reference cell resistance has drifted high
- Heater not holding the element at temperature (heater, wiring or control) medium
- ECM calibration fault on GM 2.0 turbo LTG (bulletin 16-NA-266) medium
Symptoms
- Check engine light after two consecutive drives
- Remote start refuses to start the engine (GM LTG models)
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P223E
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.