P221A
NOx Sensor 1/2 Correlation (Bank 1)
P221A compares the two NOx sensors of bank 1, upstream and downstream of the SCR catalyst. When conditions should make both read alike, the gap between them is too large, so the system cannot tell which value to trust. Volvo and Mack list P221A among codes that often lead to needless sensor swaps; before replacement a NOx conversion test must show the inlet and outlet readings disagreeing by more than about 40 ppm shortly before engine shutdown, or the cause lies elsewhere. Nissan bulletin NTB16-048 covers early 2016 Titan XD trucks with the Cummins 5.0L V8: P221A with P229E and P22A7 is fixed by a new outlet sensor and ECM reprogramming. P2201 and P229F judge each sensor alone, P221B is bank 2.
Possible causes
- One of the two NOx sensors (often the outlet sensor) reading wrongly high
- Exhaust leak between the two sensors diluting the reading medium
- ECM software (Nissan Titan XD 5.0L 2016, NTB16-048) medium
- Faulty DEF dosing distorting the comparison low
Symptoms
- Malfunction indicator lamp on
- Often stored with P20EE or other SCR codes
- Implausible NOx conversion values in live data
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for P221A
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 1 affected component(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.