P2212
NOx Sensor Heater Sense Circuit Intermittent (Bank 1 Sensor 1)
Besides driving the heater, the upstream NOx sensor on bank 1 has a sense path that reports back how the heater actually responds; GM measures heater resistance on a separate HTemp pin. P2212 means this feedback keeps dropping out or jumping instead of failing for good. No manufacturer publishes thresholds for P2212; GM's 3.0L LZ0 tables cover only the steady cases (P2208 open, P2210 short to ground, P2211 short to power). CARB requires heater circuit faults that contradict the commanded state to be caught. Typical causes are a loose contact or cracked lead that opens with heat or vibration. P2209 is a plausible but poor heater response; P2205-P2207 concern the control side. The MIL may come and go.
Possible causes
- Loose or corroded contact in the NOx sensor connector high
- Cracked conductor in the probe lead that opens with heat or vibration medium
- Intermittent fault in the sensor module's heater measurement medium
Symptoms
- Malfunction indicator lamp on, possibly intermittent
- Upstream NOx value briefly invalid
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P2212
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.