P220F
NOx Sensor Heater Control Circuit Range/Performance (Bank 1 Sensor 2)
P220F is the heater check of the rear NOx sensor on bank 1, the one after the SCR catalyst. Ford's diesel summary (it titles the code as a heater sense circuit fault) flags a heater current under 0.4 A, a short to battery or to ground, or a heater duty cycle more than 20 percent away from the expected value. Volvo and Mack use P220F with failure type 93 for their outlet sensor and recommend replacing only that sensor when the code is confirmed. Because the rear sensor confirms catalyst efficiency, a cold sensor delays or blocks the SCR monitor. P220E is the upstream counterpart; P22A3-P22A5 are the plain heater circuit faults of sensor 2. The MIL comes on, while the engine runs normally.
Possible causes
- Heater of the downstream NOx probe weak or failed high
- Heater wiring of the rear sensor shorted or with high resistance medium
- Water or salt in the rear sensor connector low
Symptoms
- Malfunction indicator lamp on
- SCR efficiency monitor not completing
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P220F
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.