P2206
NOx Sensor Heater Control Circuit Low (Bank 1 Sensor 1)
A NOx sensor needs its ceramic element heated to several hundred degrees before it can measure. P2206 means the heater control circuit of the first (upstream) NOx sensor on bank 1 reads low, typically a short to ground or a driver output stuck low. CARB requires diesel OBD to detect heater circuit opens and shorts that conflict with the commanded state. GM's 3.0L Duramax (LZ0) lists it as NOx Sensor Heater Control Circuit Low; Volvo and Mack trucks treat P2206 on the inlet sensor as an internal sensor failure and replace the sensor. P2205 is the general heater circuit fault, P2207 the high side, P2208-P2211 the heater sense circuit. The SCR system loses NOx feedback.
Possible causes
- Internal heater or control-unit fault in the NOx sensor high
- Heater wiring chafed to ground near the exhaust medium
- Moisture or corrosion in the sensor connector low
Symptoms
- Malfunction indicator lamp on
- SCR or emissions warning on the display
- Usually no change in driveability
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P2206
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 4 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?