P20C5
Reductant Heater D Control Circuit/Open
P20C5 covers an open control circuit in reductant heater D, the fourth heating element that only a few SCR layouts carry. Deutz is the one maker found that publishes the code: in its EMR5/MD1 fault list D is the downstream line heater, and P20C5 maps to SPN 520471 with FMI 5, an open or too little current. FCA's 3.0 L EcoDiesel also has a heater 4 (see P20C6), but no public document names P20C5 for it, and vehicle makers give no thresholds. Detection most likely follows the method GM documents for its heaters 1–3, which pinpoints an open with the output switched off, Type A once 2 s have passed. CARB requires output components to be checked for circuit faults. A broken wire, a loose connector or a burnt-out element in the heated downstream line are the likely causes.
Possible causes
- Heating wire in the downstream DEF line burnt out or broken high
- Loose or corroded heater D connector medium
- Wire break in the harness to heater D medium
Symptoms
- Warning lamp in cold weather
- Dosing delayed while the downstream line thaws
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P20C5
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 1 affected component(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.