P20C4
Reductant Heater C Control Circuit High
P20C4 marks heater C's control circuit as high, meaning it sees battery voltage where none belongs. GM's 2025 tables test heater 3, a second tank heater, with the output switched off against a raised voltage window and set a Type A fault after 2 s of persistence. GM's LML documentation from 2014 (6.6 L) has the glow plug module react to over 3.5 V on the heater pin while the heater should be off (Type B). Deutz lists its return line heater with FMI 3, voltage above normal. No public service bulletin names P20C4, so the main suspects are harness damage near a supply wire and an output stage that stays on. An element that keeps heating with the engine off drains the battery; once the module locks it out, that section freezes. Open and low faults of heater C are P20C1 and P20C3.
Possible causes
- Heater C control wire in contact with a battery feed high
- Heater driver in the DEF or glow plug module stuck on medium
- DEF crystals or moisture bridging pins in the heater connector low
Symptoms
- Check engine light and SCR warning
- Battery drained overnight if the heater stays powered
- Inducement and speed limit if left unrepaired
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P20C4
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 1 affected component(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.