P20C3
Reductant Heater C Control Circuit Low
A low C circuit points to heater C being grounded somewhere or drawing excessive current. GM's 2025 DEF module treats heater 3, its second tank heater, exactly like heaters 1 and 2: a low-band voltage with the output off, or drain voltage and current limits with it on, Type A once 2 s have elapsed. On the 2014 LML Duramax (6.6 L) the glow plug control module reports heater currents above 25 A within about 1 s (Type B). The best-documented case is GM bulletin 22-NA-112: on 2020–2022 Silverado and Sierra with the 3.0 L LM2 or 6.6 L L5P, P20BB and P20C3 could set without any defect, and a recalibration of the DEF control module changed the test. Deutz maps the code to its return line heater (FMI 4). On those trucks software comes first; elsewhere look for a chafed harness.
Possible causes
- Outdated DEF control module calibration on 2020–2022 GM diesel pickups (22-NA-112) high
- Heater C wire grounded through chafing medium
- Shorted heater C element drawing overcurrent low
Symptoms
- Malfunction indicator lamp, possibly with no real fault present
- Driver message that speed will be reduced without service
- Unheated tank or line section in frost
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P20C3
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 1 affected component(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.