P20B0
Reductant Metering Unit Temperature Sensor Circuit Intermittent/Erratic
P20B0 flags a metering unit temperature signal that jumps or drops out for brief moments instead of failing steadily. Housing, pump and fluid store a lot of heat, so the real temperature cannot change in leaps; the software treats such steps as a signal defect. Loose terminals, a harness rubbing against the frame near the tank and connectors exposed to road splash and thermal cycling are the main suspects. Since the fault comes and goes, it may well be inactive at the moment of inspection, and wiggling the harness while watching live data helps more than a single resistance reading. No manufacturer documents P20B0 publicly, so the actual jump limits remain unknown.
Possible causes
- Loose or spread terminal in the module connector high
- Harness chafing intermittently against frame or tank bracket medium
- Moisture entering the connector during wet or freezing conditions medium
Symptoms
- Warning lamp that comes and goes
- Temperature value jumping in live data
- Fault often not reproducible in the workshop
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P20B0