P20A8
Reductant Injection Air Pressure Control Valve Circuit Low
P20A8 says the air pressure control valve's drive circuit sits at too low a level, which normally means a short to ground. Depending on whether the valve is switched on the high or the low side, this either stops the valve from opening at all or energizes it without command. In both cases the controller loses control of the atomizing air. The fault differs from P20A6, where the circuit is interrupted, and from P20A9, a short toward battery voltage. No manufacturer documents P20A8 publicly. For the comparable valves of its air-assisted system, Deutz lists the high-side short to ground as P2060 on the air pump or supply valve and as P1061 on the air switching valve. CARB requires such circuit checks on every electrical component of the SCR system. A chafed harness on the frame rail is the classic finding.
Possible causes
- Harness chafed through to ground along the frame high
- Solenoid coil shorted to the valve body medium
- Water in the connector creating a path to ground medium
Symptoms
- MIL or SCR lamp on
- Blown fuse possible on high-side switched valves
- Dosing stopped, derate on trucks
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P20A8
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 1 affected component(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)