P206A
Reductant Quality Sensor Circuit
The quality sensor sits in the DEF (AdBlue) tank, usually inside a module that also holds level and temperature elements, and estimates urea concentration, in GM's case by timing ultrasonic echoes. P206A is the general circuit code: the module cannot deliver a usable quality value, without a finer split into range, low or high. Deutz uses it with failure-type bytes: on the EMR L1 controller P206A-21 and P206A-22 mean the quality value left its valid range at the bottom or top, on EMR5 P206A-01 stands for erratic or incorrect data. FCA lists P206A for its 3.0L diesel trucks from model year 2016 among the codes that start the Service DEF countdown: the engine can no longer be restarted once 150 miles pass without repair. Without a trustworthy reading the controller cannot detect wrong fluid, which CARB requires.
Possible causes
- Corroded or loose connector at the tank sensor module high
- Failed quality sensor or tank sensor module medium
- Damaged signal or supply wiring near the tank medium
- Frozen, aerated or heavily contaminated fluid around the sensor low
Symptoms
- MIL and DEF system warning
- Countdown to no-restart or speed limit
- DEF quality value missing in scan data
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for P206A
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?