P2055
Reductant Injection Valve Circuit High (Bank 1 Unit 2)
P2055 is set when the control line of DEF injector 2 on Bank 1 is shorted to battery positive. In GM's 2025 diesel table (25OBDG04B) the power stage of metering valve 2 reports the short; with more than 11 V and 30 faulty readings out of 60 the ECM stores a Type A fault, just as P2049 does for valve 1. Deutz assigns failure type 12 (voltage above normal or short to the high source) to metering unit 2 on EMR5 engines. On Ford's 2023 diesels the code instead describes a coil resistance more than 2 ohm above expectation, which hints at corroded terminals or an ageing winding. Whatever the platform, a driver that detects overvoltage is disabled, so the second dosing point delivers nothing until the circuit is repaired.
Possible causes
- Control line of injector 2 shorted to battery positive high
- Coil resistance too high, corroded terminals (Ford definition) medium
- Defective output stage for valve 2 low
Symptoms
- MIL on
- Second dosing point inactive
- Increased NOx emissions
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P2055
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 1 affected component(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.