Reductant Injection Valve Circuit Low (Bank 1 Unit 2)
P2054 flags a ground short in the switched circuit of the second DEF injector in the Bank 1 line. GM's 2025 diesel table (25OBDG04B) checks DEF metering valve 2 for this with the key on, the engine not cranking and more than 11 V, then sets a Type A code after 30 of 60 samples. Deutz uses P2054 on EMR5 engines for metering unit 2 with failure type 11, voltage below normal. Ford's 2023 diesel summary lists P2054 next to the circuit checks of its single injector but defines it as a resistance deviation below minus 2 ohm, so on a Ford the code points to a coil whose resistance has drifted low rather than to a second valve. Typical causes are a pinched wire, a shorted coil or a wet connector; the affected valve stops dosing.
Possible causes
- Pinched or chafed wire to injector 2 touching ground high
- Coil resistance too low due to shorted turns (Ford definition) medium
- Water or DEF in the injector connector low
Symptoms
- MIL on
- Dosing at the affected valve stopped
- DEF warning message