P2051
Reductant Injection Valve Circuit Low (Bank 2 Unit 1)
P2051 reports a ground fault on the drive wire of the DEF injector assigned to Bank 2, unit 1. Like its siblings P2050 and P2052, it presupposes a twin-bank SCR system with a dedicated valve per exhaust branch, and no manufacturer publishes a calibration or bulletin for it. The comparable Bank 1 tests give an idea of the limits: GM's 6.6 L LML flags less than roughly 0.5 ohm to ground for 2 s, and Ford's 2023 diesel logic reacts to valve current above 1.6 A. Where the second branch's harness passes hot exhaust parts, damaged insulation is the first thing to inspect. CARB treats the valve as a monitored component; once the code sets, that branch stops dosing and its NOx conversion collapses.
Possible causes
- Insulation melted or chafed near the Bank 2 exhaust high
- Shorted coil in the Bank 2 injector medium
- DEF crystals in the connector creating a path to ground low
Symptoms
- MIL on
- Dosing on Bank 2 switched off
- Possible NOx efficiency code for Bank 2 later
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P2051
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 1 affected component(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.