Reductant Injection Valve Circuit/Open (Bank 2 Unit 1)
The DEF (urea) injection valve drive circuit at bank 2 unit 1 is open — no continuity through the solenoid winding or harness.
SystemPowertrain
Typegeneric / SAE
GroupP2
Range / number– / 50
Possible causes
- Solenoid winding open high
- Pin pushed back out of connector body low
- Cracked solder joint inside the module or sensor low
Symptoms
- Check engine light or NOx warning on
- AdBlue/DEF level or quality warning
- Possible no-start countdown after ignore period
- Failed emissions inspection (NOx)
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
- Estimated cost: 120–900 €
- Estimated time: 0.7–3 h
- Component: reductant injection valve
- MIL / check engine light
- emissions-relevant