P204D
Reductant Pressure Sensor Circuit High
P204D is the high-side counterpart: the pressure signal sits near or above the supply voltage, typically because the signal wire touches 5 V or battery voltage, the sensor ground is open, or the sensor has failed internally. Published limits are 4.80 V on GM's 6.6 L LML, 98 % of the supply in GM's 2018 diesel table, 4.90 V in GM's 2025 DEF controller and 4.85 V on Ford's 2023 diesels. GM's 2014 Cruze diesel logs it as Type B, the other GM tables as Type A. Deutz's EMR L1 calls the same state a short circuit to battery. To the controller such a reading could look like over-pressure, which is why it stops the pump; check the connector at the pump module and the sensor ground before replacing the module.
Possible causes
- Open sensor ground or corroded ground terminal high
- Signal wire shorted to 5 V reference or battery voltage medium
- Internal failure of the pressure sensor in the pump module medium
Symptoms
- MIL on (after two trips on some GM diesels)
- DEF pump stopped, no dosing
- DEF warning and later inducement
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P204D
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 1 affected component(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.
Sources
- gsi.ext.gm.com/gmspo/mode6/pdf/2014/14OBDG10 Engine Diagnostics.pdf
- gsi.ext.gm.com/gmspo/mode6/pdf/2014/14OBDG04 Engine Diagnostics.pdf
- gsi.ext.gm.com/gmspo/mode6/pdf/2018/18OBDG04 Engine Diagnostics.pdf
- gsi.ext.gm.com/gmspo/mode6/pdf/2025/25OBDG04B.pdf
- fordservicecontent.com/Ford_Content/catalog/motorcraft/obd-summary-diesel-2023.pdf
- serdia.deutz.com/fileadmin/contents/serdia/DTCList_EMRL1_SecondaryECU_EN.pdf