P204C
Reductant Pressure Sensor Circuit Low
P204C means the DEF pressure sensor output has fallen below its valid range, which points to an open signal wire, a short to ground or a missing 5 V supply. On the 6.6 L LML, GM fails anything under 0.41 V lasting 0.4 s, GM's 2018 diesel table a raw value under 5 % of the supply, and the 2025 DEF controller less than 0.45 V in 6 of 100 samples, each Type A. Ford's 2023 diesels set it under 0.2 V. On 2017 to 2019 Super Duty trucks with the 6.7 L, Ford (TSB 19-2315) found water entering connectors C3613 and C4851 of the reductant harness and replaced harness, pump/heater assembly or tank. Deutz uses failure type 11 for it on the EMR5. Lacking a pressure value, the controller suspends dosing.
Possible causes
- Water intrusion in the reductant harness connectors (Ford TSB 19-2315) high
- Signal wire open or shorted to ground medium
- Missing 5 V reference to the sensor medium
- Failed sensor in the pump/heater assembly low
Symptoms
- MIL on
- DEF dosing stopped, DEF warning messages
- Further reductant codes stored at the same time
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P204C
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 1 affected component(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.
Sources
- gsi.ext.gm.com/gmspo/mode6/pdf/2014/14OBDG10 Engine Diagnostics.pdf
- gsi.ext.gm.com/gmspo/mode6/pdf/2025/25OBDG04B.pdf
- fordservicecontent.com/Ford_Content/catalog/motorcraft/obd-summary-diesel-2023.pdf
- static.nhtsa.gov/odi/tsbs/2019/MC-10167191-0001.pdf
- serdia.deutz.com/fileadmin/contents/serdia/DTCList_MD1_DE_EN.pdf