P203E
Reductant Level Sensor A Circuit Intermittent/Erratic
P203E stands for a level sensor A signal that keeps dropping out or jumping. FCA explains it best: Ram HD trucks with the 6.7L Cummins (2019–2021) carry an ultrasonic level sensor that needs an air gap above the fluid. Bulletin 18-034-21 and STAR case S2025000001 name an overfilled tank as the main trigger, because the echo no longer returns; residual ice or urea crystals in the focus tube after hard frost do the same. Returned parts were mostly found free of faults. The test only runs with ambient and tank above about 4 °C, so the fix is draining 2 to 3 gallons or thawing the tank, then about 15 min of steady highway driving. Jeep and Ram 3.0L EcoDiesel software updates (18-018-14, 18-018-15) also cover P203E. Steady circuit faults belong to P203C/P203D.
Possible causes
- DEF tank overfilled, no air space for the ultrasonic echo high
- Residual ice or urea crystals covering the sensor high
- Intermittent contact at the tank connector medium
- Control unit software needing an update low
Symptoms
- MIL and Service DEF message
- DEF gauge jumps or reads 0 % with fluid in the tank
- Warning returns after filling or after a cold night
Inspection / repair
- Difficulty: easy
- DIY: possible
What Pro shows you for P203E
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 1 affected component(visible in Pro mode)
- 4 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.