P0EFD
Battery Charger A Input Voltage Sensor C Circuit Low
P0EFD reports that the reading of input voltage sensor C in charger A sits below its plausible band. No manufacturer documents P0EFD publicly. GM's 2011 Volt charger module gives a reference for sensor A: once AC is detected at the inlet, a peak value under 90 V for 1500 ms within a 1875 ms window sets P0D3F, Type A with the warning lamp after one trip. Causes on the measuring side are a short to ground on the sense path, a shorted lower divider resistor or a missing reference for the converter. A phase that is genuinely dead at the supply, such as a tripped breaker on one leg of a three-phase station, can produce the same picture, so the incoming voltage is measured first. Mains undervoltage proper has its own codes such as P0D27; the high counterpart is P0EFE.
Possible causes
- One phase missing at the supply (tripped breaker or fault in the station or cable) medium
- Sense path of channel C shorted to ground medium
- Defective divider or converter input for channel C in the charger high
Symptoms
- AC charging refused right after plugging in
- Charging works on a different station or outlet
- Charging fault message
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0EFD
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.