P0EE2
A/C Refrigerant Distribution Valve B Stuck/Open
P0EE2 says the second refrigerant distribution valve, B, stays open or fails to close. In plug-in hybrids and EVs such shut-off valves route refrigerant either to the cabin evaporator or to a chiller that cools the battery; Egelhof sells solenoid versions with 12 V or 24 V coils for exactly this use. The fault is inferred, since the module sees pressures or temperatures that would not occur with the valve shut. Audi documents it on the A7 55 TFSI e (2021-2023): P0EE200 is stored in thermal management unit J1024, address 00C5, and the MIL comes on. TSB 2071040/1 blames the J1024 software and lists an SVM update from container 4K8909476J/K/L to 4K8909476V; the HV charging cable must be unplugged during flashing. Valve A stuck open is P0EC9.
Possible causes
- Thermal management software misjudging the valve (Audi J1024) high
- Valve seat contaminated or armature stuck open medium
- Weak coil that no longer moves the armature low
Symptoms
- MIL on
- Weaker cabin or battery cooling
- Often no noticeable effect beyond the warning
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0EE2
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.