P0ED6
Generator Phase X Current High
P0ED6 is stored when the current in phase X of the hybrid generator exceeds its permitted limit. No manufacturer documents P0ED6 publicly. Ford gives figures for the comparable U, V and W codes P0A71, P0A74 and P0A77 on its 2019 power-split hybrids: the motor/generator control unit declares overcurrent once the generator current magnitude passes 300 A for 400 microseconds, or 15 A for 200 ms just after power-up, when practically no current should flow. Genuine overcurrent points to a winding short, damaged insulation or a power switch that fails closed; a current sensor with too much gain triggers a false alarm. The inverter shuts down to protect itself, so the hybrid system may stop working. Low side: P0ED5; general code: P0ED4.
Possible causes
- Turn-to-turn or ground short in the phase X winding medium
- Inverter power switch failed closed medium
- Current sensor reading too high (false overcurrent) medium
Symptoms
- Sudden hybrid system shutdown or loss of ready mode
- MIL and hybrid warning
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended