P0ED5
Generator Phase X Current Low
P0ED5 means that phase X of the hybrid generator carries, or appears to carry, too little current while the generator is supposed to deliver torque. No manufacturer documents P0ED5 publicly. Mitsubishi publishes a comparable check for the U, V and W phases of the 2023 Outlander PHEV: with at least 50 A requested and the generator between 500 and 4,500 rpm, a phase current that stays within roughly 17 A of zero for 0.4 s sets P0E0C, as does a failed comparison with the target current. In phase X the same result comes from a broken phase cable, a burnt winding joint, an inverter switch that never conducts, or a current sensor stuck at its zero point. P0ED6 is the high case; the low codes of phases Y and Z are P0ED8 and P0EDB. Generator torque and charging suffer.
Possible causes
- Open or loose phase X cable or terminal high
- Inverter power switch for phase X not conducting medium
- Burnt or broken winding connection in the generator low
- Current sensor stuck near zero low
Symptoms
- Weak or no battery charging by the generator
- Rough engine start or vibration from the generator
- MIL and hybrid warning
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0ED5
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 4 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?