P0ECE
Hybrid/EV Battery E Voltage Low
P0ECE sets when the voltage of hybrid/EV battery E remains below the window the controller expects for the present load and charge. Its counterparts are P0ECF for too high and P0ECD for unstable readings. No manufacturer documents P0ECE publicly. Ford publishes a comparable low test for battery A (P0B25) on its 2019 hybrids, based on calculated state of charge: if any cell reaches 0 % for 10 seconds with the main contactors closed, or for 90 seconds with them open, the code is set. A unit that discharged itself during long standstill, a module with an internal short, or a balancing circuit that keeps draining one group can pull unit E down. The controller then reduces discharge power, so electric range and boost shrink and the engine runs more often on hybrids.
Possible causes
- Unit E deeply discharged after long standstill or a high self-discharge cell high
- Internal short or capacity loss in a module of unit E medium
- Balancing switch stuck on and draining one cell group low
- Voltage sense fault reading low low
Symptoms
- Reduced electric range and acceleration
- Engine starts more often, EV mode unavailable
- MIL and battery warning
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0ECE
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.