A/C Power Supply Relay Control Circuit High
P0EC8 indicates that the relay control circuit for the A/C power supply carries too high a voltage, typically a short to a battery-fed wire. A low-side driver then pushes current straight into that short when it switches on; modern output stages detect the overcurrent, turn themselves off and log this code, so the relay stays open and the A/C components get no power. With a high-side driver the same fault can hold the relay on permanently. No manufacturer documents P0EC8 publicly. CARB explicitly lists shorts toward a higher voltage as a circuit fault that output component monitoring must catch. Look for wires rubbing on a powered conductor or a shorted coil. Low side: P0EC7; clutch relay analogue: P0647.
Possible causes
- Control line shorted to a battery-fed wire high
- Relay coil with too low resistance overloading the driver medium
- Incorrect relay type fitted low
Symptoms
- A/C has no power and stays off
- Relay may stay energised permanently on high-side switched designs
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P0EC8
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
See repair cost, labour time and components?