P0EC6
A/C Power Supply Relay Control Circuit/Open
P0EC6 concerns the control side of the relay that switches power to air conditioning components, typically the compressor or climate electronics. The module driving the relay coil notices that its output does not behave as commanded, most often because the coil circuit is open. No manufacturer documents P0EC6 publicly, and the exact wiring differs by maker. CARB requires output components to be checked either functionally or for circuit continuity and shorts, and lets manufacturers report open and shorted states under one code, which is the role of this umbrella code. A relay that never pulls in leaves the A/C without power. Voltage-specific faults: P0EC7 and P0EC8; the clutch relay equivalent is P0645.
Possible causes
- Relay coil burnt open or relay missing high
- Open control wire or loose relay socket terminal medium
- Failed output driver in the controlling module low
Symptoms
- A/C or electric compressor completely without function
- No relay click when A/C is requested
Inspection / repair
- Difficulty: medium
- DIY: possible
What Pro shows you for P0EC6
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.