P0EA6
DC/DC Converter B Over Temperature
P0EA6 means the second DC/DC converter, B, has reached a temperature beyond its permitted limit. Unlike a temperature sensor code, the reading itself is accepted as true; the unit is simply too hot and will normally reduce or stop its output to protect itself. FCA lists it as DC/DC Converter 2 Over Temperature for the 2019 Cherokee (KL) with the 3.2 V6 and stop-start (sales code EHK), in its PCM reflash bulletins (18-077-22, earlier 18-023-19 REV. B), which apply to MIL complaints with a list of start-stop related codes; no threshold is published. Under CARB the function of such parts has to be supervised. Blocked cooling air, high load on the 12 V network or a weak internal power stage are typical causes. Converter A uses P0D32 for the same fault.
Possible causes
- Cooling air or heat sink of converter B obstructed medium
- Sustained high load on the 12 V network medium
- Control software misjudging the temperature condition medium
- Weak internal power stage of converter B low
Symptoms
- MIL on
- Start-stop unavailable while the converter is hot
- Electrical consumers affected during engine restart
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P0EA6
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.