DC/DC Converter Current Sensor B Circuit High
P0E9E flags the B current channel of a DC/DC converter reading above its ceiling: the raw signal lies above anything the sensor should output. With a Hall sensor whose zero lies mid-scale, this usually means the signal line touches the supply or the reference ground has opened. No manufacturer documents P0E9E publicly. Mercedes-Benz shows the same fault type on the first channel: on the EQB and G-Class, P0E5400 denotes a short to battery plus on the converter's current sensor A and shows up with red 12 V and HV warnings after a faulty wake-up; the workshop checks it with a buck-mode test of about 30 s in XENTRY and then resets the converter. Porsche calls the B channel current sensor 2 and has its low fault as P0E9D. A real overcurrent belongs to P0D33.
Possible causes
- Sensor B signal shorted to supply voltage high
- Open reference ground of the current sensor medium
- Converter in an error state after wake-up, cleared by reset low
Symptoms
- Red 12 V battery or HV warning
- Converter stops supplying the 12 V network
- Reduced drive power possible
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0E9E
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?