P0E98
DC/DC Converter Voltage Sensor C Circuit Low
P0E98 is set when the C voltage channel of a DC/DC converter is stuck at the lowest end of its range, typically because the measuring line is grounded or the sensing stage has lost its supply. No manufacturer documents P0E98 publicly. GM's 2025 tables (25OBDG03A) show the matching test on channels A and B of the 12 V stabiliser used for auto-starts: below 1 V in 320 out of 400 readings at a 12.5 ms rate gives P0E33 or P0E38, rated Type B. A third channel would be judged the same way. CARB calls for range monitoring of inputs like this. If the converter output itself is normal on the other channels, the fault lies in the C path. The high counterpart is P0E99.
Possible causes
- Sensor C signal line shorted to ground high
- Measuring stage without supply or with an open signal path medium
- Internal defect in the converter's measuring circuit low
Symptoms
- MIL on, depending on the manufacturer's rating
- Converter output reduced or switched to a fallback value
- Start-stop or 12 V support may be disabled
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for P0E98
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.