P0E93
Drive Motor B Inverter Voltage Sensor B Circuit Low
With P0E93 the controller sees the B voltage channel in the motor B inverter stuck near the bottom of its signal range, as happens with a short to ground, an open signal path or a failed measuring circuit. No manufacturer documents P0E93 publicly. Mitsubishi's rear motor sensor A on the 2023 Outlander PHEV gives a comparable limit: its low code P0DA5 sets once the signal sits at or below 0.55 V for 0.3 s with the rear motor unit powered at 8 V or more, and the checks start with the battery management and the high-voltage cables to the rear motor before the motor unit itself. Drive motor A has the equivalent sensor B fault as P0E8E. If several channels read low together, missing high voltage is more likely than a sensor fault. Motor B is normally disabled until the reading is valid.
Possible causes
- Measuring circuit for channel B in the motor B inverter failed high
- Signal line shorted to ground or open medium
- High-voltage cable or connection to motor B open, no voltage at the inverter low
Symptoms
- MIL and EV system warning
- Rear or second motor without power, front-drive only
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0E93
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 4 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.