P0E6F
Battery Charging System Precharge Contactor Control Circuit Low
P0E6F points to the coil control line of the charging precharge contactor sitting too low, most likely shorted to ground. With a high-side driver the coil then cannot be energised, so precharge never starts; the driver itself may shut down to protect itself. No manufacturer documents P0E6F publicly. GM notes for the comparable high-side monitor of its positive charging contactor (P0D0A, 2019 hybrid tables) that it cannot detect a short to ground at all, which is why a separate low code makes sense. Mitsubishi's i-MiEV stores P0AE6 when the coil feedback of its charging contactor stays off while the module commands it on; it names wiring, the contactor and the EV-ECU as causes. P0E70 is the high counterpart, P0E6D an open coil circuit.
Possible causes
- Coil control wire shorted to ground inside or near the battery high
- Shorted turns in the contactor coil medium
- Driver stage switched off by its overcurrent protection low
Symptoms
- Charging does not start, contactor click missing
- High-voltage fault message when plugging in
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended