P0E67
Battery Charger Control Circuit High
P0E67 is set when the charger command line reads higher than commanded, for instance close to battery voltage while the control unit is holding it off. A short to a live wire is the classic cause; with some driver designs an open line also floats high and lands here. The risk is the reverse of P0E66: depending on how the signal is defined, the charger may see a permanent request and try to start, or the module may stop charging as a precaution. No manufacturer documents P0E67 publicly. GM covers the line in the 2016 Volt (VICM) only with the general code P0E65, Type B, 30 of 40 samples at 25 ms. CARB expects a plug-in hybrid to detect charger malfunctions that disable or restrict charging, which applies here as well.
Possible causes
- Control wire shorted to a battery feed or other supply high
- Open line read as high by the driver circuit medium
- Output stage of the control unit stuck switched on low
Symptoms
- Charging aborted or not offered at all
- Charger wakes up or runs without a charging request
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P0E67
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.