P0E65
Battery Charger Control Circuit/Open
P0E65 flags a fault on the wired command line through which the hybrid control unit operates the on-board charger, most often an interrupted line. GM uses it codegenau: in the 2016 Volt the VICM runs the test, in the 2019 hybrid tables (19OBDG01) the HPC2 module. The check relies on a fault flag raised by the output driver hardware itself and only runs while system voltage is 10.2 V or higher and the charger enable mask is active. Samples are taken every 25 ms; 30 bad ones among 40 store the code. GM classes it Type B, so the MIL comes on once the fault returns on a second trip. Low, high and plausibility faults on the same line have their own codes, P0E66 to P0E68. Plug-in charging is usually refused until the line is repaired.
Possible causes
- Broken or disconnected charger control wire high
- Corroded or pushed-out terminal at charger or control unit medium
- Defective output driver in the commanding control unit low
Symptoms
- Vehicle does not charge when plugged in
- MIL after the second trip with the fault (GM)
- Charging fault message in the instrument cluster
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P0E65
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 1 warning for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.