P0E41
Charge Status Indicator B Control Circuit Low
P0E41 refers to a second charge status light, indicator B, whose driver circuit is pulled too low, usually by a short to ground. Which light carries the letter B is the maker's choice; a lamp at the charge port alongside the dashboard light would be a typical pair. No manufacturer documents P0E41 publicly, and the GM Volt and ELR tables only cover indicator A. By analogy with GM's P0D2C test on light A (12OBDG01A), a ground short would be checked while the LED is commanded on, with 40 of 50 samples at 100 ms. Because indicator B usually sits in the exposed charge port area, a pinched harness or water ingress there deserve the first look. Indicator A keeps working if only B is affected. The open-circuit code for B is P0DE5, the high case P0E42.
Possible causes
- Indicator B wire pinched to ground near the charge port flap high
- Water ingress into the charge port light assembly medium
- Shorted LED in indicator B low
Symptoms
- Second charge light (e.g. at the port) stays dark
- Main charge indicator and charging unaffected
Inspection / repair
- Difficulty: medium
- DIY: possible
What Pro shows you for P0E41
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.