P0E02
Generator Phase U Current Sensor Circuit Low
P0E02 is stored when the output of the generator inverter's phase U current sensor falls to the bottom of its range, a level no real current would produce. Mitsubishi uses it on the Outlander PHEV: from model year 2023 the generator control unit, supplied with at least 8 V, sets P0E02-00 once the U-phase signal drops to 0.5 V or lower and stays there for 0.2 s; unlike the zero-point test, no standstill is needed. The 2018 code chart describes the same code as a ground short or a broken line at current sensor 1. Because the sensor is built into the power drive unit, Mitsubishi's procedure ends with replacing that unit after a confirming drive cycle. The offset check is P0E01, the opposite fault P0E03. Without a valid U-phase value the generator usually runs only in a limited way.
Possible causes
- Sensor signal shorted to ground or sensor output failed low high
- Open signal or supply connection of the sensor inside the power drive unit medium
- Input stage of the generator control unit faulty low
Symptoms
- MIL and hybrid system warning light on
- Generator power limited or generator not used
- Battery charge falls faster in hybrid operation
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended