P0DF9
Generator Inverter Temperature Sensor C Circuit High
P0DF9 is stored when the C temperature sensor of the generator inverter reports a voltage at or beyond the upper end of its window. For the Outlander PHEV Mitsubishi defines the limit as 3.75 V for 0.08 s on the W-phase high-side IGBT sensor, monitored continuously whenever the GCU has at least 8 V. An open line, a backed-out terminal in the inverter connector or a broken sensor element are the usual explanations. Unlike a real cold start, the reading does not climb as the generator works, which separates the fault from a true low temperature. Generator power may be held back until the value is valid again, and Mitsubishi fixes it by replacing the complete power drive unit. Too low a voltage on the same sensor is P0DF8; the B-sensor counterpart is P0DF6.
Possible causes
- Open signal line of sensor C medium
- Terminal pushed back in the inverter connector medium
- Broken sensor element inside the power drive unit medium
Symptoms
- Engine or hybrid warning light on
- Inverter temperature stuck at a very low value
- Generator output held back
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0DF9
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.