P0DF5
Generator Inverter Temperature Sensor B Circuit Low
P0DF5 sets when the signal voltage of generator inverter temperature sensor B stays below its valid window. Mitsubishi's Outlander PHEV checks this continuously: if the V-phase high-side IGBT sensor reads at most 1.25 V during 0.08 s while the generator control unit has at least 8 V supply, P0DF5-00 is stored. Mitsubishi does not say which temperature this means, but with a thermistor whose resistance falls as it warms, a low voltage looks like an extremely hot switch, the usual picture of a short to ground or a shorted element. The guided repair ends with a new power drive unit because the sensor is internal. Expect reduced generator power while the fault is present. The high case is P0DF6, an implausible in-range value P0DF4.
Possible causes
- Signal line shorted to ground medium
- Shorted thermistor inside the IGBT module medium
- Internal fault of the power drive unit medium
Symptoms
- Engine or hybrid warning light on
- Generator output limited, engine runs more often
- Displayed inverter temperature implausibly high
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0DF5
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.