P0DE2
Hybrid/EV Battery Cell Balancing Circuit N Stuck Off
P0DE2 closes Ford's list of balancing codes: circuit N does not discharge when commanded. Ford's 2018 hybrid summary has the BECM judge this during a 100 ms window at key-on, contactors still open, comparing each of the six cells with the average against 75 mV over two power cycles. A switch that stays open has no immediate effect on driving, but the imbalance adds up. Intersil's application note AN141 puts numbers on this: cells count as matched when their capacities lie within 3 percent, and a gap of only 150 mV at full charge can cost a series pack a quarter of its capacity or more. Group N will therefore be full first and limit what the whole pack can store. Stuck-on counterpart: P0DE1.
Possible causes
- Open bleed resistor in circuit N high
- Balancing switch of group N not turning on medium
- Cell tap of group N detached from the busbar low
Symptoms
- Check engine light without driving complaint
- Charging ends early because group N is full first
- Electric range shrinking over months
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0DE2
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.