P0DDF
Hybrid/EV Battery Cell Balancing Circuit M Range/Performance
P0DDF covers group M when balancing responds but its outcome is not credible. No manufacturer publishes this code. Ford patent US9145064B2 shows what the expected outcome can be built on: the controller derives a bleed time per cell from that cell's surplus capacity and the charging current, so that all cells arrive at the target together at the end of charging. If group M is still out of line once its time is used up, the plan or the hardware behind it is off. Typical reasons are a capacity estimate that no longer matches an aged cell or a resistor that has drifted. The CARB hybrid rule in 13 CCR 1968.2 calls for exactly this functional check. Electrical fault of M: P0DDC.
Possible causes
- Stored capacity value for cells of group M out of date medium
- Battery controller software (update before repair) medium
- Bleed resistor of M drifted low
Symptoms
- Check engine light following charging sessions
- Group M not aligned with the rest after full charge
- Inconsistent range display
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0DDF
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.