P0DDD
Hybrid/EV Battery Cell Balancing Circuit M Stuck On
P0DDD reports a balancing path of group M that keeps conducting. Ford's 2015 hybrid OBD summary places it in the BECM monitor, judged at power-up before the contactors close: 100 ms, six cells per circuit, more than 75 mV from the average, two consecutive power cycles. A properly working chip should never leave a channel on indefinitely. Infineon's TLE9012DQU, for example, gives each cell its own balancing timer of up to about 3.9 hours and ends balancing on its own once that runs out, or when its over- or undercurrent check trips. If group M still loses charge after such limits, the switch itself is most likely shorted. Expect a low group M after a night of parking. Inactive counterpart: P0DDE.
Possible causes
- Shorted balancing switch of group M that no timer can stop high
- Damaged external balancing transistor on the board for M medium
- High self-discharge cell in group M imitating a stuck switch low
Symptoms
- Check engine light at start-up
- Group M noticeably low after overnight parking
- Raised module temperature near group M
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended