P0DDA
Hybrid/EV Battery Cell Balancing Circuit L Stuck Off
P0DDA says circuit L does not discharge when it is told to. In Ford's 2019 hybrid OBD summary the start-up test has been simplified: it still runs for 100 ms before the contactors close, but the requirement of two consecutive power cycles is gone, and the 75 mV deviation of a cell from the average must instead persist for 0.1 s. Ford's 2014 code list flags the code for the MIL. Renesas patent US9735567B2 explains why a switch that never closes can be seen electrically: a pull-up lifts the balancing pin to cell potential, so a switch that is told to close while the pin still shows the full cell voltage means the path is open. Group L then lags behind in every balancing run and limits the charge. Opposite case: P0DD9.
Possible causes
- Balancing switch of group L stays open when commanded on high
- Bleed resistor of circuit L open medium
- Missing gate drive for the balancing switch of L low
Symptoms
- Check engine light with no change in drivability
- Group L reaches full charge before the rest
- Gradual loss of usable capacity
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0DDA
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.