P0DD6
Hybrid/EV Battery Cell Balancing Circuit K Stuck Off
P0DD6: group K's bleed path stays dead when balancing is called for. Ford includes it in its 2017 hybrid OBD summary; the BECM decides at power-up with open contactors, within 100 ms and over two power cycles, using the 75 mV deviation of one of the six cells from the average. LG's patent US20110285539A1 offers a direct check of the path: a sampling capacitor first takes on the cell's voltage and is then emptied through the balancing circuit; whatever voltage is left over must be close to zero, otherwise the circuit is faulty. Because nothing is drained, the car drives normally, but group K keeps reaching full charge first and the pack loses usable capacity. The stuck-on counterpart is P0DD5.
Possible causes
- Open bleed resistor in circuit K high
- Balancing switch of group K failing to turn on medium
- Cracked solder joint in the balancing path of K low
Symptoms
- Check engine light while the car drives normally
- Group K highest at the end of charging
- Electric range decreasing over many charges
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0DD6
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.