P0DCD
Hybrid/EV Battery Cell Balancing Circuit I Stuck On
P0DCD tells that circuit I is drained although no balancing is wanted. In Ford's 2014 hybrid OBD summary the code belongs to the start-up check with open contactors; that early version only sets it after the 75 mV spread within the six-cell group has shown up on two consecutive power-ups. A diagnosis must also know when a switch is on deliberately. Samsung SDI's patent US11327122B2 turns balancing switches on in groups to warm the voltage monitoring chip when it is cold, and switches them off again as the chip warms up. Such intended activity must not count as stuck on; a switch that keeps conducting after every command to open does. Expect group I to lag after parking. CARB section (e)(15.2.3) accepts checks on the switches themselves. Inactive case: P0DCE.
Possible causes
- Balancing switch of group I permanently conducting high
- Software leaving a deliberate switch activation (e.g. chip warming) active low
- Driver stage of the monitoring chip stuck active on channel I medium
Symptoms
- Check engine light with hybrid battery warning at start-up
- Group I lower than the rest after longer standstill
- Shorter electric range
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0DCD
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 4 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.