P0DCA
Hybrid/EV Battery Cell Balancing Circuit H Stuck Off
P0DCA flags circuit H as inactive: balancing was ordered, but group H keeps its charge. Ford includes the code in its 2017 hybrid OBD summary, again decided by the start-up comparison of six cells per circuit with the pack average. Not every pause is a fault, which makes this code tricky. TI's BQ79616-Q1 stops a channel when its timer runs out, when the cell drops below a programmable floor between 2.45 and 4 V, on an unmasked fault, or for a thermal pause. A controller has to separate such intended stops from a bleed path that never conducts, for instance an open resistor or broken tap. Over many charges the unbalanced group H caps the charge. Under 13 CCR 1968.2 this must be detected. Opposite: P0DC9.
Possible causes
- Bleed resistor of group H open high
- Broken cell tap or weld on the balancing lead of H medium
- Intended stop (timer, thermal pause) wrongly judged as no response by the software low
Symptoms
- Full charge reached earlier, with less range than before
- Cells of group H stay at the top of the cell list
- Check engine light
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended