P0DC9
Hybrid/EV Battery Cell Balancing Circuit H Stuck On
P0DC9: the bleed path of group H keeps conducting. Ford lists the code for its 2016 hybrid and plug-in BECM, judged at start-up from the cell spread within the six-cell circuit. Besides draining charge, a switch that cannot open turns energy into heat around the clock. Monitoring chips are built to limit that heat: TI's BQ79616-Q1 pauses all balancing when sensors next to its internal bleed FETs exceed about 105 °C, or when a thermistor near the external resistors passes a set limit. A shorted FET ignores such a pause, so the hot spot persists. Expect group H to sit low after standstill. The CARB rule permits judging balancing by switch response. Circuit fault: P0DC8, inactive case: P0DCA.
Possible causes
- Bleed FET of group H shorted and unaffected by thermal pause high
- Heat damage on the monitoring board around the bleed resistors of H medium
- Chip logic keeping the balancing enable of channel H active low
Symptoms
- Check engine light and hybrid battery warning
- Group H noticeably lower than the rest after parking
- Locally raised temperature reading in the battery module
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0DC9
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 4 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?