P0DC2
Hybrid/EV Battery Cell Balancing Circuit F Stuck Off
With P0DC2 the controller concludes that circuit F does not bleed when asked to, so the fullest cells of group F are never trimmed. Ford's 2014 hybrid OBD summary applies the same 75 mV deviation test over the six cells of each circuit as for the stuck-on code, but the 2014 to 2018 versions want the deviation seen at two power-ups in a row, before the contactors close. The practical cost lies in charging: the group that cannot shed charge reaches its upper limit first and stops the charge for the whole pack. An Intersil (now Renesas) application note estimates that lithium cells 150 mV apart at full charge can lose up to a quarter of usable pack capacity. CARB's section 1968.2 counts the missing response as a malfunction. The always-on opposite is P0DC1.
Possible causes
- Bleed resistor of group F burnt open high
- Bleed transistor of circuit F no longer conducting medium
- Loose cell tap or connector pin on the balancing lead low
Symptoms
- Charging ends earlier than usual, displayed full charge gives less range
- Cells of group F remain highest after charging
- Check engine light, usually without noticeable driving change
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0DC2
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.