P0DBA
Hybrid/EV Battery Cell Balancing Circuit D Stuck Off
P0DBA: circuit D refuses to bleed. Toshiba's patent US20130026994A1 lists an open balancing terminal as one of the faults a monitoring chip should report, and this is the typical root of a stuck-off result. Because no charge is taken away from the high cells in group D, the pack's top end is governed by them; the charger and the controller stop earlier and the displayed range creeps down. The fault rarely causes a sudden breakdown. CARB 13 CCR 1968.2 requires balancing to stay functional. Ford uses P0DBA in its hybrid BECM (OBD summary 2015); the stuck-off decision comes from comparing the six cells of circuit D with the pack average at power-up, 75 mV being the limit. The always-on opposite is P0DB9, the overall verdict P0DAB.
Possible causes
- Open balancing terminal or cell tap in group D high
- Bleed resistor of circuit D open medium
- Balancing transistor of circuit D failed open low
Symptoms
- MIL and battery warning
- Range slowly decreasing, charging finishing early
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0DBA
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.