P0DB9
Hybrid/EV Battery Cell Balancing Circuit D Stuck On
A stuck-on circuit D (P0DB9) drains group D continuously. The usual check is simple: does the switch state reported back equal the state the controller asked for? GM applies this on the eAssist battery for a related code, sampling every 200 ms and logging a Type B fault after 7 mismatches in 10. Here the reported state stays on while the command says off. Besides the voltage loss, the bleed resistor keeps warming its part of the module, which can upset temperature readings nearby. On Ford hybrids the code is real: the 2019 OBD summary checks circuit D for 0.1 s at each start, before the high voltage contactors close, against a 75 mV deviation of any of its six cells from the average. The broken-circuit case is P0DB8, the inactive case P0DBA.
Possible causes
- Balancing transistor of circuit D shorted high
- Status feedback of the module wrong, switch actually fine medium
- Drive output of the monitoring chip stuck on low
Symptoms
- MIL with battery warning
- Group D cells and their local temperature deviating
- Loss of charge while parked
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0DB9
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 4 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.